GoodmanSeasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed
Diagnosis first, numbers second - you approve the repair price before a single part goes in.
Get your free estimateWhy Atlanta Homeowners Choose Lennox HVAC
Halden Heating and Air Atlanta provides independent Atlanta Lennox service across metro Atlanta, from emergency no-cool calls in Buckhead to full Signature Series replacements in Decatur. We’re not a Lennox dealer or authorized factory shop, and we won’t pretend otherwise. What we bring is roughly two decades of hands-on Lennox field time: variable-speed inducer failures on EL296V furnaces, inverter board errors on XC25 heat pumps after Atlanta’s humid lightning seasons, and rusted condensate pans on 1990s R-22 systems still limping through Sandy Springs summers. The short version: if it says Lennox on the data plate, one of our techs has probably opened one up this month. Call (912) 616-5481 and we’ll give you a written price before any tool comes off the truck.
Why Trust Halden Heating and Air Atlanta for Your Lennox HVAC?
Andre Fuller, owner of Halden Heating and Air Atlanta, learned HVAC fundamentals at Los Angeles Trade-Technical College before spending the better part of twenty years fixing equipment across Atlanta neighborhoods. He’s done emergency no-cool calls in Buckhead and full system replacements in older Inman Park bungalows. His approach hasn’t changed since day one: tell you exactly what’s wrong, what it costs, and what happens if you do nothing. Every Lennox repair starts with a written price, not a handshake and a maybe. He still shows up with a legal pad and writes the quote down by hand before opening a tool bag. “We write it down before we touch anything, that’s not a policy, that’s just respect.”
Our techs carry Lennox-specific diagnostic experience on the G26, EL296, G71, and Variable Capacity series. That experience came from thousands of independent repairs across metro Atlanta, not factory training. It means we know exactly where the pressure switches sit on an SLP98V and which firmware quirks show up on iComfort communicating thermostats after a power surge. Every Lennox job we complete is covered by our 365-Day Done Right Promise, which means a full year of accountability in writing. If the repair fails within the coverage window, the return visit is free. No arguing, no fine print, no “that part was working when we left.”
Parts matter with Lennox, and we’re specific about them. On sealed-system and safety components like boards, gas valves, and heat exchangers, we use genuine Lennox OEM parts. On common wear items like capacitors and ignitors, we’ll use proven aftermarket options when they match or beat the original spec, because paying triple for a branded capacitor doesn’t make your AC colder. We install OEM where it protects your warranty and your safety, and we tell you which is going in before we order it.
Styles & brands we work with






Common Lennox HVAC Problems We Fix in Atlanta
- Variable-speed inducer motor failures on EL296V furnaces. The EL296V uses a variable-speed inducer that ramps to specific torque profiles for low-fire and high-fire operation. When that motor starts to fail, it can’t hit the low-fire profile, and the control board reads it as a pressure switch fault. The furnace either locks out or throws intermittent error codes that come and go with the weather. In Atlanta’s damp spring mornings, we see this pattern constantly: the unit runs fine on dry afternoons, then drops a “pressure switch open” code at 3 a.m. when humidity spikes. The fix is replacing the inducer assembly with OEM, then verifying differential pressure with a manometer so the board sees what it expects to see.
- Inverter board communication errors on XC25 and XP25 Signature units. The Dave Lennox Signature Collection XC25 air conditioner and XP25 heat pump use a variable-capacity inverter drive, which is the component that lets the unit modulate output from roughly 25% to 100% capacity instead of cycling on and off. After Atlanta’s summer lightning season, we get a steady run of calls where the outdoor unit just won’t talk to the indoor air handler. The iComfort thermostat shows a communication fault, and the outdoor board often shows no error at all. Power surges and nearby strikes damage the inverter board’s communication circuit. We replace the board with OEM, re-establish the system address, and the unit is back to modulating. Without factory-level familiarity with these units, that diagnosis can take hours. With it, it usually takes about forty minutes of methodical testing.
- Heat exchanger rust-through on G26 series furnaces. The G26 is a workhorse from the 1990s, and Atlanta’s humidity is not kind to it. We still find G26 furnaces in Buckhead, Sandy Springs, and Decatur basements where the original heat exchanger has rusted through along the lower crimp lines. What does that mean for you? Carbon monoxide can leak into the airstream, which is why the rollout switch trips and shuts the unit down. When we find a tripped rollout switch on a G26, we do a full heat exchanger inspection with a combustion analyzer before we reset anything. If the exchanger is breached, it’s not a repair, it’s a replacement recommendation. We’ve condemned more G26 heat exchangers in Atlanta than we can count, and we’ll never send a furnace back into service with a cracked exchanger, no matter how much the homeowner wants one more winter out of it.
- Evaporator coil leaks on 10-15 year old Merit Series condensers. Merit Series is Lennox’s entry-level line, and the condensers are solid units. The weak point on older Merit AC systems in Atlanta is actually the evaporator coil, which sits inside the air handler or furnace plenum. After 10-15 years of pulling humid Atlanta air across the coil, the copper tubing at the coil’s return bends develops formicary corrosion, which is a fancy way of saying tiny pinholes form from acid compounds in the air. The coil loses refrigerant slowly, cooling performance degrades, and eventually the system can’t keep the house below 78°F on a 95°F day. We pressure-test with nitrogen, find the leak, and because the coil is at the end of its useful life, we usually recommend coil replacement or full system replacement depending on compressor age.
- Frozen evaporator coils on variable-capacity XC systems. This one is Atlanta-specific. The XC25’s variable-capacity compressor ramps down to very low output on mild days to maintain temperature without short cycling. That’s efficient, but it also means the evaporator coil runs cold for long periods. In Atlanta’s humid shoulder seasons, when the system runs at low capacity for hours, condensation can build up on the coil and freeze if airflow isn’t perfect. The usual culprits are a dirty filter, a blower motor running slightly slow, or low refrigerant from a slow leak. We check airflow first, then refrigerant charge, then the EEV (electronic expansion valve) operation. On a communicating system, the thermostat will usually tell you something is wrong before the ice gets bad, but by the time you see frost on the refrigerant lines, shut it down and call us at (912) 616-5481.
Lennox Parts & Our Repair-vs-Replace Approach
Lennox parts pricing varies wildly between OEM and aftermarket, and a good service provider tells you the difference. On safety and sealed-system components, OEM is the right call. A genuine Lennox control board is designed to match the exact voltage tolerances and communication protocols of your EL296V or SLP98V. A generic board might work today and fail in six months, and if it takes out your gas valve on the way, that repair just got a lot more expensive. We stock a rotating inventory of common Lennox boards, pressure switches, flame sensors, and ignitors on our trucks, because waiting three days for a board in August is not acceptable when you need AC Repair in Atlanta.
For wear items like capacitors, contactors, and ignitors, we use proven aftermarket parts from manufacturers we trust. A capacitor doesn’t know what brand sticker is on it, and the electrical specs matter far more than the logo. Our rule: never let the parts bill exceed the replacement value of the equipment. If your 14-year-old Merit Series AC needs a compressor, a coil, and a fan motor, we’re going to tell you the honest math: $3,500 to $7,500 for a new system versus maybe three patched-together years at $2,800. We’ll give you both numbers in writing and let you decide. Call (912) 616-5481 if you want a straight answer on whether to repair or replace your Lennox system.
Our Lennox Service Process – Step by Step
- 1
Diagnosis with Lennox-specific tools. We show up with the right diagnostic equipment for your system: manometers for verifying inducer differential pressure on EL296V furnaces, communication testers for iComfort systems, and leak detectors calibrated for R-410A. Before we touch anything, we write down the price. Not an estimate range. A fixed number. The legal pad comes out before the tool bag opens.
- 2
Repair with the right parts. For safety and sealed-system work, we install genuine Lennox OEM parts and show you the old part and the new part before anything goes back together. For wear items, we tell you if we’re using aftermarket and why, and the price reflects that choice. No mystery parts, no “trust me” moments.
- 3
Testing against manufacturer spec. After the repair, we test the system the way Lennox engineers intended it to run. That means verifying gas pressure on furnaces, checking superheat and subcooling on AC systems, running the unit through a full heating or cooling cycle, and confirming every safety switch operates correctly. We don’t just clear the error code and walk; we make sure the underlying condition is actually gone.
- 4
Written guarantee and before-you-leave walkthrough. Every repair comes with a written guarantee, covered under our 365-Day Done Right Promise. If the repair fails within the coverage window, we come back at no charge. Before we leave, we walk you through what was wrong, what we fixed, and what to watch for. That’s not a sales pitch; it’s just how a service call should end.
See the difference
Before
After
Before
After
Before
AfterLennox Products We Service & Install in Atlanta
Our techs service and install Lennox HVAC in East Point, GA and across Atlanta, handling the full range of equipment commonly found in local homes. That includes the Merit Series (ML180, ML296 furnaces and matching AC condensers), the Elite Series (EL296V and EL280 furnaces, plus Elite AC and heat pump models), and the Dave Lennox Signature Collection (XC25 air conditioners, XP25 heat pumps, and SLP98V variable-capacity gas furnaces). We also work on the older G26 and G71 series furnaces that are still common in 1980s-2000s Atlanta tract housing. We stock common Lennox consumables locally, including flame sensors, ignitors, pressure switches, and capacitors, so we can complete most repairs on the first visit. Mini split installs are a growing part of our Lennox work, especially for older intown bungalows where ductwork is undersized and a traditional split system would fight the house’s natural airflow.
We Also Service These Brands
Lennox is a focus of ours because Atlanta has so many of them, but we’re not a single-brand shop. We service and install Carrier and Trane equipment as well, and our techs carry diagnostic experience across all three brands. If you have a mixed system, a Carrier condenser paired with a Lennox air handler, we can work on both without pointing fingers at the other brand.
FAQs – Lennox HVAC Service in Atlanta
Why does my Lennox EL296V furnace run the blower constantly even when the thermostat is satisfied?
The EL296V uses a variable-speed blower motor controlled by the furnace’s integrated control board, and constant low-speed airflow is a feature when the unit is set to continuous fan mode or when the thermostat is configured for air circulation. If you haven’t selected continuous fan, the usual cause is a thermostat setting that’s stuck, a shorted thermostat wire, or a control board that’s received a false fan signal. We check the thermostat programming first, then the wiring, then the board. If the board is misreading inputs, we replace it with OEM and the blower behavior returns to normal.
Can you recharge my Lennox XC25 with R-410A without finding the leak?
We won’t, and no reputable company should. Adding refrigerant to a leaking system is a temporary patch that wastes your money and releases refrigerant into Atlanta’s atmosphere. The XC25 is a high-efficiency variable-capacity unit, and its performance depends on a precise refrigerant charge. If it’s low, there’s a leak. We find the leak with an electronic detector or nitrogen pressure test, fix the leak properly, then charge the system to manufacturer spec. The exception: if the leak is in the evaporator coil on a 12+ year old system, we’ll often recommend replacing the coil or the whole system rather than repairing a component that’s at the end of its service life. Call (912) 616-5481 and we’ll give you an honest assessment.
My Merit Series AC froze up and shut off. Is this a capacitor or refrigerant issue?
A frozen coil is rarely a capacitor problem. The capacitor starts the compressor and fan motors; if it fails, the unit usually won’t start at all. A frozen coil means the evaporator is getting colder than it should, which points to low airflow or low refrigerant. Low airflow comes from a dirty filter, a failing blower motor, or collapsed ductwork. Low refrigerant comes from a leak somewhere in the system. In Atlanta’s humidity, restrict flow is even more common because humid air holds more moisture, which accelerates frost formation. We check airflow first because it’s free to inspect, then we check pressures to see if the system is undercharged. The fix depends on which one it is, and the price reflects that.
What does the error code ‘E228’ mean on my Lennox communicating thermostat?
E228 on a Lennox iComfort thermostat is a communication error between the thermostat and the outdoor unit or indoor equipment, usually the result of a wiring fault, a power interruption, or a failing control board. After Atlanta thunderstorms, the code often appears because a power surge or brief brownout scrambled the system’s bus communication. The fix might be as simple as a full system power cycle and a firmware re-check, or it might require replacing a damaged communication board. We see enough of these that we carry diagnostic tools specifically for Lennox communicating systems, which lets us isolate the fault quickly instead of swapping parts at random. Call us at (912) 616-5481 and we’ll walk through a power-cycle procedure over the phone before we roll a truck.
Should I replace my 15-year-old Lennox G26 furnace heat exchanger or buy a new furnace?
If your G26 heat exchanger is cracked or rusted through, replace the furnace. A G26 is from the 1990s, which means the entire unit is well past its designed service life. Replacing a heat exchanger on a furnace that old is a multi-thousand-dollar repair on equipment that will likely fail again within a few years, and the new heat exchanger won’t restore the efficiency or safety of a modern system. A new Merit Series or Elite Series furnace with a 10-year parts warranty will save you money on gas, run quieter, and actually be safe to operate. Atlanta has thousands of G26s still in service, and every year we condemn more of them. We’ll give you the replacement number and the repair number in writing, and we’ll recommend replacement every time when the heat exchanger is done.
How much does Lennox HVAC service cost in Atlanta?
For Lennox in Union City and throughout Atlanta, AC repair typically runs $150 to $650, and furnace repair runs $150 to $700, depending on the part and labor. If your system needs full replacement, a new single-stage AC installation runs $3,500 to $7,500 in the Atlanta market. Tune-ups start around $80 and top out at $200 for a comprehensive inspection. The specific number for your system depends on what’s wrong and what parts it needs, so call (912) 616-5481 for an exact written quote. Estimates are free, and we put the price on paper before any work starts.
| Service | Price Range (Atlanta) |
|---|---|
| AC Repair (diagnostic + typical repair) | $150 – $650 |
| Furnace Repair (diagnostic + typical repair) | $150 – $700 |
| AC Installation (single-stage, 2-ton) | $3500 – $7500 |
| Tune-Up (furnace or AC) | $80 – $200 |
Book Your Lennox Service in Atlanta, GA
If your Lennox system is acting up, or you want a second opinion on a repair quote, call Halden Heating and Air Atlanta at (912) 616-5481. A real person answers 24/7. We’ll schedule a time, send a background-checked tech with a live arrival time you can track, and put your price in writing before we touch anything.
Written by Andre Fuller, Owner at Halden Heating and Air Atlanta, serving the Atlanta metro area since 2004.